CE marking · Windows & doors
EN 14351-1:2006+A2:2016
Initial type testing for the CE declaration of performance — air, water, wind, thermal and acoustic.
- Laboratory
- SGS Guangzhou (Notified Body 0598)
- Issued
- Jan 2025
9 · Certificates & test reports
Third-party certificates and laboratory reports for every system and market we supply. Preview any document, or request the full signed report.
EN 14351-1:2006+A2:2016
Initial type testing for the CE declaration of performance — air, water, wind, thermal and acoustic.
NFRC 100 / 200 / 500
Certified U-factor, SHGC, VT and condensation resistance ratings for US and Canadian energy codes.
AAMA/WDMA/CSA 101/I.S.2/A440-17
North American Fenestration Standard testing for structural, water and air performance grades.
AS 2047-2014 · AS 4420
Australian window standard testing for cyclonic-region wind classes plus WERS energy ratings.
CSA A440S1-19
Canadian supplement testing for −35°C cold climates, including air leakage and condensation.
ISO 9001:2015
Quality management covering extrusion, finishing, fabrication, glazing and export packing.
Qualicoat Spec. 16th ed.
Coating line approval for super-durable powders and the Seaside pre-treatment for coastal sites.
UAE Fire & Life Safety Code · Estidama
Material and façade compliance for Gulf projects, including solar control and fire performance.
PHI Certified Component · cool-temperate
Certified as a Passive House window for cool-temperate climates, efficiency class phB.
01 — Tested performance
Every system is tested by accredited third-party laboratories — SGS, Intertek and the Guangdong Building Science Research Institute. Full reports are shared with buyers before ordering.
Water tightness
EN 12208 · Class E900
900Pa
Static pressure with water spray — equivalent to a 140 km/h storm.
Wind load resistance
EN 12210 · Class E2400
2,400Pa
C80 casement tested at 1.5 × 1.8 m with less than L/300 deflection; S90 lift & slide reaches C5 (2,000 Pa).
Air permeability
EN 12207 · Class 4
4/ 4
Highest European class — under 3 m³/h·m² at 100 Pa.
Acoustic insulation
ISO 10140 · Rw
45dB
With laminated acoustic glass — a busy street becomes a library.
Hardware endurance
EN 1191 · Class 3
30,000cycles
Opening & closing cycles without loss of performance.
Thermal performance
0.9W/m²K
Uw on C80 with triple glazing — meets Passive House, Energy Star Northern Zone and NCC 2022 Section J.
Request a quote
Tell us about your project and an export manager will reply with system recommendations, an itemised quotation and lead time — free, with no obligation.