Lift & slide doors
ARC-S90 / S120 Slim
- Wind
N4 / C1
Need: N2
- Water
900 Pa
Need: 150 Pa
- Energy · glass
Uw 1.55 · g 0.23
Need: Uw ≤ 4.00 · g ≤ 0.5
Recommended glassDouble solar-control Low-E · aluminium spacer

Buyer tools · Code compliance
Choose the city and building. We derive the wind, water and energy requirements in your local standard's own terms, check every ARCVIEW system against them and give you a summary your certifier or consultant can review.
Optional requirements
Indicative requirements
2 × 3 m = 6 m · Suburban · Residential · New build
AS/NZS 1170.2 TC3, Ms 0.95
Wind load
AS 4055 / AS 2047
N2
500 Pa · 10.4 psf
AS 4055-2021 · AS/NZS 1170.2:2021 · AS 2047-2014
Water tightness
AS 2047
N2
150 Pa · 3.13 psf
AS 2047-2014 Table 2.1
Energy
NCC 2022 climate zone 5 · Class 1/2 DTS glazing
≤ 4.00
Max. Uw W/m²K
Typical value — whole-building method
NCC 2022 Vol. 1 Section J / Vol. 2 H6 · NatHERS · WERS
Indicative — not a certificate. These figures are simplified from the cited standards for early product selection. Topography, building shape, local amendments and project specifications can change them. Always verify with your structural engineer, certifier or façade consultant before ordering.
02 — System matrix
Every system is compared with its tested values. The recommended glass is the most economical glass and spacer combination that meets the energy limit at the standard reference size.
5 pass · 0 conditional · 0 not suitable
ARC-S90 / S120 Slim
N4 / C1
Need: N2
900 Pa
Need: 150 Pa
Uw 1.55 · g 0.23
Need: Uw ≤ 4.00 · g ≤ 0.5
Recommended glassDouble solar-control Low-E · aluminium spacer
ARC-C70 / C80 Thermal
N5 / C2
Need: N2
1,050 Pa
Need: 150 Pa
Uw 1.47 · g 0.41
Need: Uw ≤ 4.00 · g ≤ 0.5
Recommended glassDouble Low-E, argon · aluminium spacer
ARC-F68 / F80 Heavy
N3
Need: N2
300 Pa
Need: 150 Pa
Uw 1.84 · g 0.44
Need: Uw ≤ 4.00 · g ≤ 0.5
Recommended glassDouble Low-E, argon · aluminium spacer
ARC-CW150 Stick / Unitized
C4
Need: N2
1,500 Pa
Need: 150 Pa
Uw 1.24 · g 0.26
Need: Uw ≤ 4.00 · g ≤ 0.5
Recommended glassDouble solar-control Low-E · aluminium spacer
ARC-P100 Monolith
N3
Need: N2
300 Pa
Need: 150 Pa
Uw 1.38 · g 0.21
Need: Uw ≤ 4.00 · g ≤ 0.5
Recommended glassDouble solar-control Low-E · aluminium spacer
03 — Beyond the numbers
Documents, labels and approvals your inspector or consultant will ask for. Where we hold a matching test report, it is linked.
The label shows the manufacturer, rating (N/C class, SLS, ULS, water) and product; certifiers check it on site.
AS 2047-2014 §9 · NCC 2022 H2D7 / J4D
Our test reports:AS 2047 & WERS
Doors, side panels and low-level glass need toughened or laminated safety glass to the local standard.
AS 1288-2021 · AS/NZS 2208
Your energy assessor needs certified Uw and SHGC values (WERS) for the NatHERS or DTS glazing calculation.
NCC 2022 · NatHERS 7-star · WERS
Our test reports:AS 2047 & WERS
Next step
Download a branded compliance summary with the requirements, sources, system matrix and assumptions — or send the project to our engineers for a free review against your drawings.
Free · reply within 1 business day