ARCVIEWALUMINIUM SYSTEMS

Buyer tools · Thermal

U-value calculator. Pass the energy code before you specify.

Size the unit, choose the glass, spacer and profile depth, and see the whole-window Uw per EN ISO 10077-1 update as you type — with the U-factor in Btu, the g-value, the condensation risk at your design temperature and the code limits it meets.

Configuration

System
mm
400 mm4000 mm
mm
400 mm2600 mm
Panels / leaves
1

≤ 1400 × 2400 mm · 1,230 mm

Profile depth
Glazing
Spacer (warm edge)
Condensation check

Condensation check

°C
-30 °C10 °C
°C
15 °C26 °C
%
20 %80 %
Whole-unit resultEN ISO 10077-1

Uw1.37W/m²K

U-factor
0.241 Btu/h·ft²·°F
Solar factor gw
0.41 g 0.60

Where the heat goes

  • Glass55%
  • Frame32%
  • Glass edge13%
Frame fraction
31%
Glass area
1.25 m²
Unit area
1.82 m²
Perimeter
5.42 m

Indicative EN ISO 10077-1 calculation with tabulated Uf, Ug and ψ values. Verify with your energy consultant or certifier; the declared Uw on the CE / UKCA declaration of performance is the value of record.

Code limits Indicative

6/12 · Uw 1.37

  • Passive House componentPHI · ≤ 0.80 W/m²KFail
  • ENERGY STAR NorthernUS · ≤ 1.25 W/m²K · U ≤ 0.22 BtuFail
  • Part L 2021 notional (new build)UK · ≤ 1.20 W/m²KFail
  • ENERGY STAR CanadaCA · ≤ 1.22 W/m²KFail
  • GEG (Germany)DE · ≤ 1.30 W/m²KFail
  • MaPrimeRénov' (France)FR · ≤ 1.30 W/m²KFail
  • Part L 2021 replacementUK · ≤ 1.40 W/m²KPass
  • ENERGY STAR North-CentralUS · ≤ 1.42 W/m²K · U ≤ 0.25 BtuPass
  • Part L 2021 limitingUK · ≤ 1.60 W/m²KPass
  • CTE DB-HE zone D/E (Spain)ES · ≤ 1.80 W/m²KPass
  • ENERGY STAR SouthernUS · ≤ 1.82 W/m²K · U ≤ 0.32 BtuPass
  • Dubai Green Building RegulationsAE · ≤ 1.90 W/m²KPass

Limits are indicative maximum Uw values for windows in new or replacement work; national rules vary with building type, compliance route and reference size. ENERGY STAR and NFRC rate U-factor at NFRC sizes and boundary conditions, so an EN ISO 10077 value is only a first check.

ELEVATION1,230 mm1,480 mmSECTION A–AOUTIND 80 mmIGU 24 mm

Condensation risk

Borderline

Ti 20 °C · RH 50% · Te -10 °C

Dew point 9.3°
15.7°
9.8°
14.5°
Centre of glass
15.7 °C
Glass edge
9.8 °C
Frame (inside)
14.5 °C
Dew point
9.3 °C

The coldest surface is within 3 K of the dew point. Upgrade the spacer or profile depth, or ask for a 2-D THERM/Flixo check.

Uw1.37W/m²K · g 0.41

02 — Buyer FAQ

U-value questions from specifiers

Brochure values are declared at the EN 14351-1 reference size of 1.23 × 1.48 m with the best glass. Your unit's size, panel count, glass and spacer change the frame fraction and edge losses. Large sliding doors usually beat the reference value; narrow windows with several sashes lose to it.

Request a quote

Send us your drawings. Get a factory price in 48 hours.

Tell us about your project and an export manager will reply with system recommendations, an itemised quotation and lead time — free, with no obligation.

  • Reply within 24 hMonday–Saturday, in English, Spanish, French or Arabic.
  • Itemised quote in 48 hPer-unit pricing, glass & hardware specs, window schedule.
  • Prefer WhatsApp?Message us with your drawings — we read PDFs and DWGs.
I am a
Attach drawings (optional)

We never share your details or drawings. Privacy policy

Get a factory quote in 48 h